BCQWS - PVC INSULATION

  • MSDS: BCQWS
  • Manufacturer: CLAUD S GORDON COMPANY
  • Product Name: PVC INSULATION
  • National Stock Number: 5970-00N008722
Product Identification

Product ID:PVC INSULATION
MSDS Date:06/23/1986
FSC:5970
NIIN:00N008722
MSDS Number: BCQWS

Responsible Party
CLAUD S. GORDON COMPANY
5710 KENOSHA ST
RICHMOND, IL 60071
US

Emergency Phone: 815-678-2211

Info Phone: 815-678-2211

Cage: 93768

Contractor
CLAUD S. GORDON COMPANY
RICHMOND, IL 60071

Cage: 93768

Ingredients

LEAD CHROMATE (OSHA PEL FOR LEAD FROM 29CFR

CAS: 7758-97-6

RTECS: GB2975000

OSHA PEL 0.05 MG/M3 (PB)

ACGIH TLV: 0.05MG/M3(CR)A2;8990


LEAD SULFATE (SARA III)

CAS: 7446-14-2

RTECS: OG4375000

OSHA PEL SEE 1910.1025

ACGIH TLV: 0.15 MG PB/M3; 9192

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


LEAD COMPOUND.NIOSH REL 0.1 MG(PB)/CUM TWA.

OSHA PEL 0.05 MG/M3 (PB)

ACGIH TLV: 0.15 MG/M3 (PB);8990


ANTIMONY TRIOXIDE (SARA III)

CAS: 1309-64-4

RTECS: CC5650000

OSHA PEL 0.5 MG/M3 (SB)

ACGIH TLV: 0.5 MG SB/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3; 9192


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293

Hazards

LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS & SYMPTOMS OF OVEREXPOSURE.
Explanation of Carcinogenicity:EVIDENCE FOR CARCIN:LEAD CHROMATE:SUFF
IN ANIMALS & HUMANS (IARC 1982);ACGIH A2=SUSPECT HUMAN
CARCINOGEN.(SEE SUPP DATA)
Effects of Overexposure:SKIN:IRRITATION FROM VAPORS PRODUCED AT
EXCESSIVELY HIGH TEMPERATURES.INHALATION:IRRITATION FROM VAPORS
PRODUCED AT EXCESSIVELY HIGH TEMPERATURES.EYES:N/K;INGESTION:N/K .
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:SKIN:IF EXPOSED TO FUMES,FLUSH WITH WATER FOR AT LEAST 10
MINUTES.INHALATION:MOVE TO FRESH AIR.IF BREATHING IS
DIFFICULT,ADMINISTER OXYGEN.CALL PHYSICIAN.EYES:FLUSH WITH LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.INGESTION:CALL PHYSICIAN
IMMEDIATELY.

Fire Fighting

Flash Point:N/K
Lower Limits:N/K
Upper Limits:N/K
Extinguishing Media:ABC DRY CHEMICAL POWDER EXTINGUISHER,WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:HAZARDOUS DECOMPOSITION
PRODUCTS:HCL,CARBON MONOXIDE,CARBON DIOXIDE GAS.

Accidental Release

Spill Release Procedures:N/K
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:N/K
Other Precautions:N/K

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .NECESSARY IF TEMPERATURE EXCEEDS 500F,260C.
Ventilation:EACH SITUATION MUST BE EVALUATED BASED UPON EXPOSURE OF
CONCERN.LOC & GEN VENT NECESSARY TO KEEP AIR CONC BELOW TLV.
Protective Gloves:N/K
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:N/K
Work Hygienic Practices:MAINTAIN GOOD PERSONAL HYGIENE PRACTICES.
Supplemental Safety and Health
NOTE:PRODUCT IS A MIXTURE WHICH HAS NOT BEEN TESTED AS A WHOLE.EVID FOR
CARCIN:CHROMIUM & CERTAIN CHROMIUM COMPOUNDS ARE KNOWN TO BE
CARCINOGENIC (NTP). ANTIMONY OXIDE:ACGIH A2=SUSPECT HUMAN CARCINOGE
N.

Chemical Properties

Boiling Pt:B.P. Text:N/K
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:N/K
Vapor Density:N/K
Spec Gravity:N/K
Evaporation Rate & Reference:N/K
Solubility in Water:N/K
Appearance and Odor:N/K

Stability

N/K
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:HCL,CARBON MONOXIDE,CARBON
DIOXIDE,FUMES.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .DISPOSE OF IN SANITARY
LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.